| 8½" (215) |
5" (127) |
1¾" (45) |
90" (2286) |
15" (380) |
30" (760) |
7½" (190) |
5¼" (135) |
| 10" (250) |
6" (152) |
2" (50) |
90" (2286)
or
120" (3050) |
N.A. |
| 12" (305) |
6" (152) |
3" (76) |
| 14" (355) |
6" (152) |
4" (100) |
| Tolerances allowable per Quality Assurance
Manual |
Thickness
ins (cm) |
Length
ins (cm) |
Standard Element - cuft (dm³) |
End
Element |
Weight Std. E.
lbs (kg) ±10% |
| Outside |
Cavity |
Net |
Net |
| 8½" (21.5) |
90" (228) |
6.64 (188) |
1.97 (56) |
4.67 (132) |
- |
112 (51) |
| 10" (25) |
120" (305) |
10.42 (294) |
3.67 (104) |
6.75 (190) |
4.22 (119) |
158 (72) |
| 90" (228) |
7.81 (221) |
2.73 (77) |
5.08 (144) |
3.17 (90) |
120 (54) |
| 12" (30.5) |
120" (305) |
12.5 (354) |
3.67 (104) |
8.83 (250) |
5.26 (149) |
197 (90) |
| 90" (228) |
9.37 (265) |
2.73 (77) |
6.64 (188) |
3.95 (112) |
148 (68) |
| 14" (35.5) |
120" (305) |
14.58 (412) |
3.67 (104) |
10.91 (308) |
6.31 (178) |
243 (110) |
| 90" (228) |
10.94 (309) |
2.73 (77) |
8.21 (232) |
4.73 (134) |
183 (83) |
Thickness
ins (mm) |
Width
ins (mm) |
Length
ins (mm) |
Weight
lbs (kg) ±10% |
| 2" (50) |
30" (760) |
60" (1525) |
50 (23) |
| 4" (100) |
30" (760) |
120" (3050) |
190 (86) |
| RASTRA® Element |
Concrete Consumption |
| 8½"
wide |
0.21 cubic feet per
square foot
of wall surface (65 dm³/m²) |
| 10", 12"
& 14" wide |
0.30 cubic feet per
square foot
of wall surface (65 dm³/m²) |
| RASTRA® Element |
Weight
of Grouted Wall
(approximate without plaster) |
| 8½" |
42 lbs/sq ft (201 kg/m²) |
| 10" |
57 lbs/sq ft (274 kg/m²) |
| 12" |
60 lbs/sq ft (288 kg/m²) |
| 14" |
64 lbs/sq ft (307 kg/m²) |
| Reinforcement Consumption |
- 15" Centers 1.17 lineal feet per square foot of wall
surface
- 30" Centers 0.85 lineal feet per square foot of wall
surface
|
TECHNICAL PROPERTIES AND
DATA OF THE RASTRA® SYSTEM |
Sound Qualities of RASTRA® Elements
The RASTRA® element has exceptional sound absorbing and attenuation qualities. This means
that the interior of the new RASTRA® structure will be shielded from most outside noises.
RASTRA® elements are very effective when creating sound resistant rooms such as Theater
Rooms, Sound Studios or Media Rooms. |
Fire Resistance
RASTRA® elements
are very effective in areas where high fire resistance is required. In full-scale tests of
RASTRA® walls it
has been shown that the RASTRA® wall does not support combustion and does not emit smoke and has a
four-hour fire rating.The fire rating, in
combination with the sound absorption qualities, makes RASTRA® a natural for multi-unit/multi-family
projects. In addition, RASTRA® has been approved as a thermal barrier.
|

|
Frost Protection - Thermal
Performance
The same component matrix THASTYRON which gives RASTRA® its fire resistance, also insulates the concrete grout placed
inside the grout channels, resulting in extreme frost protection both during the pour and
thereafter.Because of the minimal heat and cold
transfer through the RASTRA® element, the concrete grout retains its heat and moisture
longer thus allowing a consistent cure, unhindered by outside temperatures. This results
in a stronger end product.
During five-hour fire endurance testing of full-scale
10-inch (25cm) thick RASTRA® walls, applied temperatures exceeded 2000°F (1100°C) on the exposed face.
However, the recorded temperature increase on the unexposed face was just 7°F (4°C) and
that was attributed to changes in ambient temperature during the test. In essence, the
wall did not conduct heat during the test. This low conductivity together with the
thermal storage capacity of the concrete core make for excellent thermal performance
of a RASTRA® wall.
Another aspect is the low specific heat of THASTYRON,
results in a wall surface temperature close to ambient room temperature. Tests have shown
that thermostat settings can be lowered (increased for cooling) by as much as 9°F (5°C),
if the wall temperature is within ±5°F (3°C) of the comfort level.
|
Mold & Mildew
Resistance
RASTRA® elements also have other features and qualities that make it unique. Because the
component matrix THASTYRON will not hold or wick water the way concrete block or
wood products do, RASTRA® elements will not promote or sustain mold and mildew. Rot is a thing of the
past. As a building system used in Europe for more than 25 years, numerous tests have
proven RASTRA® 's
ability to resist mold and mildew.
Building materials which seal too tight, cause poor air quality in a building. The porous
composition of THASTYRON allows a slow interchange of air, which in turn, allows the
building to "breathe". The exchange is slow enough not to let heat or cold
escape but helps maintaining good air quality and prevents not only condensation but also
"sick building syndrome". |
Insect & Vermin
Resistance
Unlike solid polystyrene, the mixture of Portland cement and polystyrene creates an
undesirable atmosphere for insects. Additionally, the concrete grout placed in the
channels penetrates the pours of the THASTYRON surface, fusing the concrete and the
THASTYRON together, therefore eliminating channels that termites and other insects could
use for migration and nesting. |
|